The article presents the condition of a building temporarily out of service without adequate protection against the influence of environmental factors. The survey of the facility revealed a number of damage to the supporting structure elements. The results of non-destructive tests and laboratory tests confirmed the impact of long-term shutdown of operation on the degradation of the structure and allowed for conclusions about the possibility of returning it to use.
On the example of several pipes, the dependences between the yield strength and ultimate strength of the steel which the pipes were made from and its Brinell hardness measured directly on the tubular structural elements (in situ) was determined. Knowledge of these dependences is essential in indirect steel strength tests, through non-destructive hardness measurements, in the case of structures made of circular hollow sections. These relations differ significantly from the corresponding relations known from the tests of unalloyed steels in the raw or normalized state in hot-rolled flat elements. The work was completed with conclusions and recommendations of a practical nature
The study refers to the general requirements of the Environmental Protection Law regarding the assessment of environmental quality standards relating to the emission of vibrations from the roads in use. The article discusses the useful procedures for assessing the impact of vibrations generated by passing vehicles near the buildings. Such vibrations are a kinematic excitation for the building and can lead to damage (like cracks, damage to architectural elements, scratches in structural elements, etc.). In turn, vibrations in the building may affect the violation of the conditions of the necessary vibration comfort. They may also violate the requirements relating to the working conditions of devices sensitive to vibrations in exploited buildings. The expert task is to develop a diagnosis, as a result of which information is obtained as to whether there is a cause-and-effect relationship between the violation of the conditions for the safe operation of the building and the operation of the source of vibration. The use of the procedures described here should facilitate such diagnoses. Following the given procedures, the expert will use appropriate diagnostic tools, and the necessary information described in this study
As part of the preparations for the construction of the Central Communication Port, a set of Technical Standards was developed, including geotechnical design of earthworks, railway subgrade, bridge structures and many others. The paper presents the scope and main provisions of volume I.5 "Geotechnical investigations and design". Special requirements related to the specificity of earthworks for high-speed railways are indicated
The article describes the main load-bearing systems of long-span platforms in industrial halls. It recalls the statics and principles of forming Vierendeel frames. It shows how these frames are used in platforms, as well as discusses their advantages and disadvantages. It also includes several calculation examples. Steel consumption was calculated for classic post and beam frames and Vierendeel frames at identical loads and spans. The frames with spans between 12 m and 21 m were analyzed. The results of the analysis showed that Vierendeel frames with spans above 15 m consume significantly less steel. Therefore, they are a more economical solution for long-span platforms, accepting some of their limitations
The work concerns the analysis of characteristic flexibility of bridges with a soil-shell structure. The stiffness used for moving loads and the susceptibility useful for assessing the effects of stationary loads were analyzed. A structure model was formulated using the shell crown deflection influence line. Two approaches to the vulnerability are presented. The first concerned the construction phase of the flexibility. The second takes into account changes in the ground as a result of constant loads and bridge operation
The alterations of bridge gradeline is a main subject of the paper. For this purpose, the results of geodetic survey were used. Due to the complex shape of the deflection lines, it was necessary to apply a correction procedure, using the results of measurement of forces in the stays. This is one of the algorithms used to smooth the deflection function obtained from geodetic measurements. A global 2D numerical model with bar elements is effective for the analysis. It is especially effective in MRS applications when there is a regular arrangement of measurement points. The advantage of the algorithm is the selection of any section of the span and independence from the support conditions
The article presents the methods of strengthening R-C corbels, the effectiveness of which has been verified by experimental research. Regardless of the method used, the effectiveness of the corbel strengthening is mainly dependent on the shear span to effective depth ratio, the amount of internal reinforcement and the effort of corbel before strengthening
The cable stayed footbridge over Warta river in Sieradz was put into operation in 1979. In 2019 due to deteriorating visual condition of the stay cables, a technical expertise had been commissioned. In the year 2022 the refurbishment of the bridge was commenced, which included inter alia a complete replacement of the stay cables
The article presents the condition of a building temporarily out of service without adequate protection against the influence of environmental factors. The survey of the facility revealed a number of damage to the supporting structure elements. The results of non-destructive tests and laboratory tests confirmed the impact of long-term shutdown of operation on the degradation of the structure and allowed for conclusions about the possibility of returning it to use.
The article discusses the basic requirements as well as the most common defects of industrial floors with a top layer of polyurethane screeds. Significant defects include, among others, the thickness of the polyurethane screed layer inconsistent with the designed one, strength parameters that are too low in relation to the required ones, susceptibility to the formation of local abrasions on the screed surface, roughness and local deep damage reaching the concrete foundation. The article also gives the reasons for the formation of these defects and illustrated with examples and results of own research and indicated the causes of their formation
The article discusses various ways of determining the column buckling length of steel portal frames. Considerations were limited to in-plane buckling of the frame in which the frame is characterized as a sway. A total of three methods of determining the buckling length are presented and compared. Finally, a simplified evaluation of the effect of buckling length on the utilization ratio of the column was carried out
The article presents the historical outline, scope and results of conservation and construction works of the upper castle in Iłża carried out. These works include securing the original parts of the building, raising some of the walls, recreating the outline of the rooms, and erecting viewing terraces to make the monument available to tourists
Geotechnical design of structures for high speed railways
- 1. Instytut Badawczy Dróg i Mostów
Abstract
As part of the preparations for the construction of the Central Communication Port, a set of Technical Standards was developed, including geotechnical design of earthworks, railway subgrade, bridge structures and many others. The paper presents the scope and main provisions of volume I.5 "Geotechnical investigations and design". Special requirements related to the specificity of earthworks for high-speed railways are indicated