Szczepan Woliński

The article presents comments on the principles, scientific basis and consequences of using the acceptable level of reliability in the framework of the partial coefficient method adopted in the current version of the Eurocodes. On the basis of Polish statistics of construction disasters and statistics on the causes of fatal accidents in Poland, the reliability of structures observed over the last 26 years was estimated. An assessment of the impact of the coefficient values adopted in the EN and their values corrected in the National Annexes of 20 EU and EFTA countries on the probability of failure (exceeding the ULS) of selected structural elements was also presented. The results of analyses and calculations confirm the opinion that designing of structures using the partial coefficient method is burdened with many serious disadvantages and requires considering the possibility of making far-reaching changes, including the possibility of using even simplified probabilistic methods

30-09-2023 - Original article
Grzegorz Wandzik

Three approaches (computational models) for determining the impacts on power line towers subjected to displacements caused by ground deformation are presented. The disadvantages, advantages and difficulties in the implementation of individual models were indicated. The results of exemplary calculations made with the use of a proprietary computer program are presented. The importance of considering the flexibility of the towers in order to obtain realistic results is justified

30-09-2023 - Original article
Małgorzata Pająk, Jacek Janiszewski, Paweł Baranowski, Mateusz Pytlik

In the paper, the results from the SHPB tests of concrete specimens confined with the lead covers are presented. The analysed high strain rate was from 80 s–1 to 194 s–1. The increase of the compressive strength was noted due to strain rate sensitivity of concrete but also to confinement which caused additional inertial effects

30-09-2023 - Original article
Tomasz Nowobilski, Bożena Hoła

Each year, several thousand accidents at work occur on Polish construction sites. This article presents a methodology for predicting the consequences of accidents involving construction scaffolding on the basis of the author's screening methodology. The basis for the research was a set of data obtained from the resources of the National Labour Inspectorate concerning 200 accidents. The results of the study allow for a percentage determination of the probability of light, heavy and fatal consequences of an accident

30-09-2023 - Original article
Piotr Noakowski

Pathological behavior of a floor in a large industrial hall is presented in this paper. The failure was determined by numerous and wide cracks which formed shortly after the concreting. Due to the fear regarding the further operation the owner commissioned the clarification of the genesis and relevance of the case to the author. Appropriate investigations and analyses have proved that several mistakes in the floor design were responsible for the poor performance of the floor

30-09-2023 - Original article
Rafał Krzywoń

Bond is one of the key issues determining the effectiveness of external composite strengthening of a concrete structure. The standards used in designing use various mathematical models to predict the bond strength of FRP overlays. The results obtained in the calculations may differ even two times. The paper presents an assessment of the accuracy of bond force prediction for selected design guidelines. The results of over 800 samples taken from the literature were used for comparison. The results of analyses show that the best bond model is recomended by the Swiss standard SIA166 and CNR-DT200

30-09-2023 - Original article
Łukasz Krawczyk

The aim of the paper was to determine the influence of stirrups on load capacity of corbels at shear slenderness a/d = 0.5. In ATENA models with the same geometry and various additional reinforcement were created. The results of load capacity calculated using the nonlinear method were lower than the experimental result and higher than the code resistance. The beneficial effect of stirrups on the load capacity of the corbels was confirmed

30-09-2023 - Original article
Siergey Ihnatov

In recent years, builders more and more often have to build foundations in large cities and neighboring territories in undeveloped areas in Belarus, which were previously (25-30 years ago) considered as areas where development was not possible due to ground instability or there was ground strengthening need. This all resulted building construction cost increase. The materials of the article describes two objects (an industrial building and a 5-storey building from a complex of residential buildings) their basements reinforcement, the geological conditions, basement reinforcement solutions, foundations load field tests results, as well as a comparison of the measured settlements value with their calculated values

30-09-2023 - Original article
Krzysztof Gromysz, Łukasz Szoblik

The construction of the German Nazi concentration and extermination camp Auschwitz II – Birkenau started at the end of 1941. A barrack with the current inventory no. B-138, situated at the section BI, was then erected. The barrack has documentary and historical value. The barrack walls are characterised by low stiffness, because with the building’s plan of 36.3 m × 11.4 m, the walls are only 0.12 m thick. All the outer walls have been substantially deformed or vertically deflected. Up to 156 mm wide gaps have formed between the deformed and deflected walls and contiguous walls as a result. The stability of the walls is at risk, because a bad-quality wall was loaded with horizontal and vertical forces transmitted from the roof on the eccentricity reaching 160 mm. Deformations were progressing over time as a consequence of such forces. Individual rectification procedures is proposed. This article presents a procedure of handling the western gable wall. The deformation of the western gable wall will be removed by changing its static scheme, by inserting hinge regions into the wall along the line of selected bed joints. Separate wall patches, which could rotate relative to each other, will be created as a result of the forces acting perpendicular to the wall surface. By causing the mutual rotation of such patches, the western gable wall will the desired vertical position. The stability of such a system during rectification was analyzed and it was shown to be maintained. On this basis, it is concluded that the analyzed method of rectification of the wall is possible to implement. After the rectification, the joints of the transverse wall will be replaced, and the wall itself will be anchored to the longitudinal walls with the use of reinforcement embedded in the joints

30-09-2023 - Original article
Grzegorz Gremza, Jan Zamorowski

Interactions between foundations and ground subjected to deformations in mining area depend on the difference between displacements of the ground and flexible settled structure, subjected to dead load, climatic loads and soil action on its foundation. For such load cases, elastic-plastic computational model of the foundation-ground system with a horizontal plastic yield plateau easily implementable into engineering computer programs to perform static analysis of frame systems flexible settled in areas exposed to the continuous mining deformations were described. Based on these models, an iterative solution was used to evaluate the impact of the flexible foundation of a single-storey industrial building in deforming soil on the internal forces distribution

30-09-2023 - Original article
Julia Blazy, Łukasz Drobiec

Fiber reinforced concrete is characterized by the ability to transfer loads with increasing crack width, even after reaching the maximum load capacity. Therefore, it is necessary to observe and analyse the propagation and increase of the crack. For this purpose, the traditional measurement methods like clip gauges or linear variable displacement transducers can be used. However, the digital image correlation technique is increasingly gaining popularity as an alternative, supplementary or verifying measurement method. The article focuses on the comparative analysis of the results from direct measuring devices with the results from virtual sensors obtained in the three-point bending test and Montevideo splitting tensile test. Fiber reinforced concrete samples with three different types of polymer fibers and their different content in the concrete mix were tested

30-09-2023 - Original article
Piotr Woźniczka

Selected results of experimental tests of steel double-lap shear joints with resin-injected bolts are presented. The test carried out covered 9 specimens with M16 class 8.8 bolts. Specimens were made in accordance with the PN-EN 1090-2 standard. Two-component epoxy gelcoat resin was used for the injection. Compressive strength of the resin declared by the manufacturer is equal to 110–120 MPa. The analyzed joints were subjected to short-term and long-term loads. The influence of the size of the bolt holes on the load capacity of the joint was also taken into account. Based on conducted research, the mean values and coefficients of variation of the load capacity of analyzed joint type were determined. The results of experimental tests were compared to the results of calculations carried out according to the PN-EN 1993-1-8 standard

30-09-2023 - Original article
Robert Studziński, Artur Piekarczuk

The article presents the concept of using blind rivets to attach building infrastructure components to sandwich panels. Such a connection does not require a substructure and does not cause local thermal bridges. The lack of standard and literature guidelines limits the possibility of using such connections. The parameters that define, according to the authors of the article, the load-bearing capacity and reliability of the connection are indicated. The testbeds discussed in the article, as well as the possible failure mechanisms, can serve as a starting point for determining analytical relationships that allow a quick assessment of the scope of application of the connection

30-09-2023 - Original article
Dariusz Leń

The paper presents a calculation procedure in accordance with the principles of the component method, which allows determining the initial stiffness of flange joints loaded by a tensile force. Validation of the proposed analytical approach was carried out using the finite element method. The method presented in the paper allows for a relatively easy determination of the initial stiffness of the flange joints with quite good accuracy

30-09-2023 - Original article
Aleksander Kozłowski, Wiesław Kubiszyn, Andrzej Wojnar

The most often used in engineering practice procedures for designing anchorages of cylindrical shells constituting the shafts of free-standing steel chimneys has been presented in the paper. A comparison of calculation results obtained using these procedures, anchorages of two steel chimneys with a height of 22.6 and 93.9 m was presented. The results obtained were discussed and design guidelines were given. The guidelinescontained in the report of International Committee on Industrial Construction (CICIND) were recommended as a practical method for designing steel chimney anchorages

30-09-2023 - Original article
Aleksander Kozłowski, Damian Kukla, Damian Nykiel

The paper presents problems and challenges in measuring the displacements and strains of steel structure joints using digital image correlation system. A beam-to-column bolted extended end-plate joints were tested under static loading until failure. An Aramis 2D digital image correlation system, inductive sensors, inclinometers and electrical resistive strain gauges were used to measure the displacement and strains of the element. Strains values obtained by electrical resistive strain gauging and digital image correlation were compared

30-09-2023 - Original article
Kamil Jastrzębski, Lucjan Ślęczka

Slip factor tests were carried out for samples made of hot-dip galvanised steel sheets. They were made for dry and wet contact surfaces, according to the procedure described in Annex G of the PN-EN 1090-2 standard. The research consisted of loading the test specimens with a monotonic tensile force. The preload force in the bolts was measured before and after the test. The results obtained allow us to conclude that the coefficient of friction of dry surfaces has a slightly lower value than for samples whose surfaces were soaked before the test by placing them in water for about 12 hours

30-09-2023 - Original article
Marcin Górski, Wiktor Musiał

An analysis of the influence of selected factors on the effectiveness of the cooperation of corrugated sheet with an example steel hall structure has been shown in this paper. A spatial beam model were used in calculations. The spacing of seam and sheet-to-shear connector fasteners, the type of sheet-to-purlin fastener and the type of purlin-to-girder connection were taken into account. Optimal structural solutions for the analyzed sheething of the hall were determined

30-09-2023 - Original article
ANA M. GIRÃO COELHO

The revision of Structural Eurocodes started in 2015, following an agreement between the European Commission and CEN from 2012. This paper gives an overview of the key changes introduced in each section of the second generation of part 1-8 of Eurocode 3, which gives methods for the design of steel joints and is currently submitted for formal vote of countries

30-09-2023 - Original article
Dariusz Czepiżak, Rajmund Ignatowicz

The paper analyses the load capacity of an atypical tensile connection with an overlay placed asymmetrically and welded to the connected flat bars with a 3 mm thick one-sided L-shaped fillet weld. Tensile force is applied to the axis of the flat bars. In this asymmetrical connection, a double eccentricity of load transfer appears. The purpose of the analysis is to check whether standard norm models to estimate the load capacity of these connections are appropriate and safe. The article compares the results of the analysis according to Eurocode 3, the SOFiSTiK program, IDEA StatiCa program, and the experimental tests. Eurocode 3 calculation procedures proved to be conservative. The estimation of the load carrying capacity of the joint closest to the results of experimental studies was obtained in the SOFiSTiK program

30-09-2023 - Original article
Rafał Budziński, Lucjan Ślęczka

The joints of the portal frames made of cold-formed profiles have a different structural form compared to the joints made of hot-rolled rolled sections. For this reason, they are usually classified as semi-rigid and partial strength. The paper draws attention to the phases of joint behaviour resulting from the use of category A bolted lap joints, presents the sources of their deformation, and searches for the instantaneous centre of rotation of both connections in the joint. All these characteristics were observed during experimental tests and detailed measurements were made using digital image correlation (DIC) techniques. The M- response of two moment-resisting joints was investigated, where back-to-back channel sections with dimensions 450×80×4 were applied, with steel grade S355

30-09-2023 - Original article
Lidia Buda-Ożóg, Zdzisław Pisarek, Joanna Zięba, Damian Nykiel

The article presents the concept and experimental testing of a prototype connection of a horizontal, prefabricated cylindrical tank. The connection was designed for the Sienkiewicz MAT-BUD Sp. z o.o. company. The proposed solution for connecting prefabricated elements of the tank, does not require wet work on site. The proposed solution takes advantage of the curvature of the cylindrical tank shell, allowing the introduction of a connecting bolt. The connector, which is the subject of the experimental study, was designed for a tensile force of up to 200 kN

30-09-2023 - Original article
Edyta Bernatowska

The article deals with a problem of the identification of the forms of failure of tensioned angle members connected by one leg with bolts and determination of their ultimate tensile resistance. The results of experimental research and numerical analyzes are presented. They were referred to the design guidelines contained in domestic and foreign standards

 
30-09-2023-Original article - Pages: 458 - 462

Analiza nośności niesymetrycznego, spawanego połączenia nakładkowego

  • 1. Politechnika Wrocławska, Wydział Budownictwa Lądowego i Wodnego
Published:30-09-2023

Language versions:
22
DOI:10.5604/01.3001.0053.8867
GICID:01.3001.0053.8867


 

Abstrakt

W pracy analizowano nośność nietypowego rozciąganego połączenia z nakładką umieszczoną niesymetrycznie i przyspawaną do łączonych płaskowników jednostronną spoiną pachwinową w kształcie litery L o grubości 3 mm. Siła rozciągająca jest przyłożona w osi płaskowników. W tym niesymetrycznym połączeniu pojawia się podwójny mimośród przekazywania obciążeń. Celem analizy jest sprawdzenie, czy standardowe normowe modele szacowania nośności w przypadku takich połączeń są właściwe i bezpieczne. W artykule porównano wyniki analiz według Eurokodu 3, programu SOFiSTiK, IDEA StatiCa oraz badań doświadczalnych. Procedury obliczeniowe Eurokodu 3 okazały się konserwatywne. Oszacowanie nośności połączenia najbliższe wynikom badań doświadczalnych uzyskano w programie SOFiSTiK