Inżynieria i Budownictwo

ISSN: 0021-0315
MNiSW: 40
Inżynieria i Budownictwo
Published: 30-06-2024
Number of articles: 13
Other articles from this issue
30-06-2024 - Original article
Marcin Gorączko, Aleksandra Gorączko

This paper focuses on the possibility of the continuity of traditional values through the architecture’s formal, constructional, and plastic character, based on the analyses of a dozen or so buildings from the Uniejów region in the central part of Poland. A common feature of these structures constructed over the last 20 years was the use of soft limestone. The authors aimed to determine whether and to what extent these structures are consistent with regional rural architecture. In the analyzed area, from the second half of the 19th century to the end of the 1960s, construction based on locally exploited deposits of limestone developed dynamically, unusually in terms of materials for this part of the country. The analysis in this article covered primarily such features of the objects as the area of origin of the stone material, its purpose, the stonemasonry techniques used, the functional program of the object, and its architectural features. The article also discusses whether such contemporary architectural implementations can contribute to the popularization of abandoned stone material in the region and, at the same time, result in more effective protection of traditional construction made of local stone. It is an example of disappearing architectural heritage due to ongoing modernization or demolition

30-06-2024 - Original article
Elżbieta Janowska-Renkas, Michał Cisiński, Paweł Niewiadomski

This paper presents the results of a study of the effect of spent catalytic cracking catalyst derived from polish oil refinery used as a partial replacement of cement (in the amount of 20, 40, 60 and 80% of cement mass) in the binder on the mechanical strength of cement mortars, prepared without and with superplasticizer. It was shown that the replacement of 20% of cement, by mass, with spent catalyst increased the compressive strength of mortars without and with superplasticizer dosage by 16.7% and 24.4%, respectively, and did not deteriorate the flexural strength of samples prepared with superplasticizer. With the increasing amount of spent catalyst (above 40% by weight of cement), a decrease in the strength of mortars was observed. This indicates that spent catalyst from catalytic cracking might be a promising material as a binder replacement in cementitious composites when used in smaller amounts (less than 40%).

30-06-2024 - Original article
Andrzej Kucharczyk, Andrzej Marynowicz, Jerzy Wyrwał, Dariusz Bajno, Monika Adamska, Jolanta Anna Prusiel

The paper addresses issues related to insulating from the inside of historic partitions of half-timbered construction. Laboratory measurements were carried out to assess the feasibility of insulating such walls. For this purpose, a wall was built and placed inside a bipartite chamber, where external and internal climatic conditions were simulated

30-06-2024 - Original article
Kalina Materak, Alicja Wieczorek, Agata Kacprzak, Marcin Koniorczyk

The presented study examined the effectiveness of internal hydrophobization and its impact on the basic properties of cement-based materials such as paste, mortar, and concrete. The obtained results clearly indicate that, in addition to a significant reduction of the capillary water absorption, internal hydrophobization also improves the durability of the material and provides protection against water also in case of cyclic freezing and thawing. Internal hydrophobization using an organosilicon admixture based on triethoxyoctylsilane also ensured an increase in the contact angle for water to over 90° and limited moisture sorption in the material. Moreover, the presented results indicate the interactions of the organosilicon compound with cement, which can be observed as changes in the amount of heat released during cement hydration, impact on the microstructure of the mortar, and a decrease in the compressive strength of the mortar and concrete. Nevertheless, internal hydrophobization by organosilicon compounds such as triethoxyoctylsilane is an effective and efficient method of protecting porous cementitious materials against water and moisture, even during cyclical exposure to negative temperatures

30-06-2024 - Original article
Zbigniew Perkowski, Mariusz Czabak, Petra Bujňáková, Jerzy Wyrwał

The article presents an experiment of four-point bending of timber I-beams, the deflections of which were measured using digital image correlation (DIC). The deflection functions were subjected to a wavelet transform operation, which used the second derivative of the Gaussian distribution to determine the curvature of the beams’ axis. On this basis, the distribution of flexural stiffness of the elements was estimated, showing the potential usefulness of the DIC technique in production control and laboratory testing of prefabricated timber elements. The limitations of the proposed research method related to the need to perform numerical integration operations on discrete experimental data subject to measurement errors are also presented

30-06-2024 - Original article
Aleksandra Repelewicz

The largest church buildings were erected in Poland during the communist when there were many difficulties in obtaining planning permission for churches. When a building permit was finally granted, extremely large buildings were often built, “just in case” as it were. Today, these buildings are usually too large for their users. The problem of large churches, of which there are a great many in Poland, will be discussed with particular reference to the Archdiocese of Czestochowa, where there are 8 churches with a usable ground floor area of nearly 1000 m2 or more: six in Czestochowa, one in Zawiercie and one in Radomsko. Five of them have two levels. After redrawing the boundaries and a subsequent reduction in the parish area, the number of parishioners is too low to cover the cost of their maintenance (heating, lighting, ongoing maintenance) and repairs. This is a serious problem for the administrators of these facilities. Finding a way out of this situation is a major challenge. It is necessary to look for opportunities to use these huge spaces for other purposes, which do not conflict with a parish church’s fundamental role. Already existing solutions in some churches and potential opportunities to develop some of the premises for other needs of local communities are presented in the paper

30-06-2024 - Original article
Marcin Burdziński, Maciej Niedostatkiewicz

This paper presents a numerical simulations of a pull-out test conducted using ABAQUS software. The purpose of the simulations was to evaluate the effect of anchorage length on the bond behavior of ribbed bars in this test, based on the experiments performed. The interaction at the bar-concrete interface was modeled using a contact cohesive surface and calibrated bond-slip curves obtained from experiments. Material models were defined using mechanical parameters obtained from in-house tests on concrete and steel. The analysis shows that the bond behavior is significantly influenced by the anchorage length. Numerical simulation results demonstrate excellent convergence with laboratory tests, both in terms of the bond-slip curve and material behavior

30-06-2024 - Original article
Łukasz Gołębiowski, Michał Teodorczyk , Zbigniew Fedorczyk, Artur Piekarczuk

The article presents experimental research and numerical analysis of a building partition in frame construction. The subject of the analysis were sections of the building partition consisting of cold-bent steel profiles and plasterboard cladding. The experiment was carried out using a four-point bending test and recording a continuous load-displacement curve until failure. Next, a computational model based on the finite element method was developed to simulate the experiment. The results from the experimental tests were then compared with that obtained from the numerical analysis. The validation of the numerical model demonstrated a high level of agreement in terms of load-displacement characteristics. The use of numerical analyses provides an alternative to time-consuming experimental tests for estimating displacements of building partitions in frame construction

30-06-2024 - Original article
Paweł Kacprzak

The benefits of installing pipes and drainage manholes, as well as covering open drainage ditches in built-up areas, have been listed in the report. A cost-effectiveness indicator for the investment, taking into account proprietary weighting coefficients, has been presented, which can be used as a formal argument determining the need for modernization of existing solutions in built-up areas. The indicator serves as an objective tool in the decision-making process at the municipal level. Modernization involving the installation of pipes and covering ditches, which previously served agricultural purposes, leads to an improvement in spatial order in a given area and also contributes to the protection of the natural environment through proper water management in former agricultural areas

30-06-2024 - Review article
Wioletta Raczkiewicz

The article presents selected methods for determining the chloride content in concrete to assess the impact of chlorides on the corrosion process of reinforcement in reinforced concrete elements. Methods for assessing the chloride concentration in concrete as well as tests for determining the chloride diffusion coefficient have been described

30-06-2024 - Original article
Tadeusz Urban, Michał Gołdyn, Łukasz Krawczyk

The paper presents experimental results prestressed beam made of high-strength fiber reinforced concrete. The I-shaped beam with a height of 0.2 m and a length of 2.8 m was tested in a four-point scheme until the bending load capacity was achieved. The element was prestressed with one tendon Y1860S7 with a diameter of 12.5. The fiber reinforced concrete was made with KrampeHarex® DM12.5/0.175 fibers. Concrete was tested in compression (fc ≈ 110 MPa) and in tension, checking the resistance in both the splitting test (fct,sp ≈ 17.5 MPa) and the three-point bending test (fct,fl ≈ 11.9 MPa). After fabrication and prestressing of the beam, changes in strains on the element's surface were observed for 19 days, after which destructive test was conducted. During the test deflections and deformations of the element were recorded. The failure was as a result of bending and followed yielding of the prestressing strand and the subsequent formation of one localised crack. The calculation of the load carrying capacity in the light of the SIA 2052 standard, assuming the elasto-plastic material model of the fibre reinforced concrete, showed good agreement with the experimental results

30-06-2024 - Original article
Dominika Urbańska

The article presents the structures of guyed masts that are used as supporting structures. Masts of this type consist of a vertical shaft connected to the foundation by means of guy wires. The work focuses on two designs of measuring masts with an identical shaft, but with a different number of guy ropes at the level. The static analysis was carried out taking into account the geometric nonlinearity of the guy wires and environmental loads. The results of the analysis indicate how the static scheme of the structure affects its behavior. The conclusions from the work are applicable to specific designs of tubular masts, but may be an inspiration for further research on structures of this type

30-06-2024 - Review article
Andrzej Borkowski, Natalia Zdzieszyńska, Mariusz Szóstak

The article addresses the issue of BIM education at the academic level in Poland and provides an overview of modern methodologies for teaching BIM-related subjects. With the reports of neuroscience and the development of modern technologies, there is a need to take a new direction in student-oriented academic education, in which the main goal will be to prepare graduates for life, work and meet the challenges of a rapidly changing reality. It is necessary to introduce new forms and techniques of education focusing on the concept of deep learning and based on the latest knowledge in neuroscience, cognitive psychology, pedagogy and artificial intelligence. Authentic teaching creativity on the part of the teacher can only come from full awareness of the numerous strategies available and making a thoughtful choice among them of reliable knowledge of their impact on students

 
30-06-2024-Original article - Pages: 207 - 210

Thermal and humidity assessment of a beam wall insulated from the inside

  • 1. Politechnika Opolska, Wydział Budownictwa i Architektury
  • 2. Politechnika Wrocławska, Wydział Budownictwa Lądowego i Wodnego
  • 3. Politechnika Białostocka, Wydział Budownictwa i Nauk o Środowisku
Published:30-06-2024

Language versions:
97
DOI:10.5604/01.3001.0054.6406
GICID:01.3001.0054.6406


 

Abstract

The paper addresses issues related to insulating from the inside of historic partitions of half-timbered construction. Laboratory measurements were carried out to assess the feasibility of insulating such walls. For this purpose, a wall was built and placed inside a bipartite chamber, where external and internal climatic conditions were simulated