The paper proposes a new typology of structures using timber elements, divided into homogenous and hybrid, considering the materials from which they were made, along with presenting classification criteria and an example of use. In addition, previously insufficiently specified terms were defined, such as massive timber and light timber frame.
The paper discusses an industrial floor that was constructed on a reactive slag subbase. Five years after completion, the user reported damage caused by floor displacement. Cracks and scratches were observed in the finishing layers, particularly at the connection between the partition walls and the floor. Geotechnical and surveying investigations were carried out to determine the cause of the damage. The investigations revealed the presence of reactive slag as the subbase layer. Floor displacement measurements were taken over a four-year period, from November 2019 to November 2023. Despite being ten years since construction, uplift continues to occur. The average annual increase in displacement for the entire floor over the past three years is 6 mm, with a maximum displacement of 80 mm at the midpoint of the floor. The ongoing increase in displacement and damage makes repairing the building and maintaining its use impossible. Microscopic examinations and geodetic measurements do not indicate a stopping of the expansion processes of the subbase.
The failure and collapse of edge beam were caused by the synergy of the following factors: the improper design of beams in the axes A and E, particularly with reference to shearing and torsion, the improper design of the column in the axes A and 1, the improper design of laps in the reinforcement, the performance of laps in the reinforcement which did not match the design, and the inaccurate embedment of the beam in concrete. And lower class of concrete should be regarded as the secondary cause.
The paper discusses in detail the calculation procedures from the PN-EN ISO 10077 and PN-EN ISO 6946 standards used to determine the heat transfer through small, unventilated air cavities. In order to assess the differences in real situations, calculations of an exemplary air cavity were also performed using a computer program implementing these methods. On the basis of the analyzes carried out, a number of differences in procedures and the range of potential discrepancies in the results were demonstrated. Calculations were made for an example air void. The differences in heat fluxes were up to 11% depending on the method used.
The aim of the study was to evaluate the impact of the location of the elastic bimoment stiffeners along the length of the main beam B-E of a simple H-type beam grillage on its elastic critical resistance (ECR) from the lateral-torsional buckling condition. The obtained ECR was compared with the critical resistance determined for the grillage without bimoment stiffeners. The greatest efficiency in increasing the ECR of the grillage (around +80%) was achieved by using elastic bimoment stiffeners shifted relative to joints B and E by approximately 21–25% of the main beam span.
Assessment of the risk level of timber structures is still a challenge due to the lack of comprehensive in situ research methods. This problem is particularly important in the context of historic buildings, which, despite their seemingly solid construction, may hide significant damage. Many such facilities are used without awareness of the risks associated with material degradation. Invisible damage can lead to serious construction disasters, especially in places where beams lose their support in the walls due to the destruction of the wood at their ends. These are the places where the most serious threats occur, and yet the technical condition of these elements is practically not assessed in these areas. The article emphasizes the need for continuous research on the biological degradation of wood and the use of advanced measurement methods, such as a resistograph, to more accurately assess the technical condition of timber structures and effectively prevent their degradation.
The article presents, in the context of the guidelines of the "Long-Term Strategy for Renovation of Buildings" valid until 2050, examples of renovations of historic buildings carried out in Poland in 2018-2021, which serve as public facilities. They were designed and constructed in a manner consistent with the guidelines for the transformation of a climate-neutral economy, which stem from Article 2a of Directive 2010/31/EU of the European Parliament and of the Council of May 19, 2010. The purpose of the article is a comparative analysis of selected Polish examples of revaluation of public buildings from the point of view of the Architecture of these objects. These are: the Wagner Villa in Kostrzyn on Oder, the railway station in Białystok, the Teodor Sixt Villa in Bielsko-Biała, the office building of the Forestry Commission in Elbląg, the building of the Savings Bank in Ropczyce and the former granary in Żukowo. Also cited are the current financial tools available and the basic measures needed to ensure high energy efficiency and low-carbon performance of public buildings in the run up to 2050.
The progressive degradation of the railway track structure increases the impact of the rolling stock transferred to the track and subgrade, which requires ensuring appropriate track support through the selection of material, grain size and density of granular layers. The study presents research and analysis of increased loads transferred to the ballast. By using protective layers of the track substructure made of appropriate materials, proper conditions of cooperation between the track and subgrade are achieved, ensuring the elastic operation of the surface and minimizing its permanent deformation. Currently used methods and solutions for strengthening and stabilizing granular materials are described. Particular analysis was carried out to ensure proper support of the track grid by providing appropriate granular material and its compaction (including ballast obtained from recycled – unsorted stone).
The article describes a case study of a collegiate basilica located in northern Poland and listed in the register of monuments of the Kuyavian-Pomeranian Voivodeship under the identification number 601148. This building dates back to the 14th century and has been rebuilt many times in its history, serving both a sacred and penitentiary function. Currently, the facility is used only for religious purposes. Its owner and user set himself the goal of maintaining the temperature inside at a level of approximately +16°C all year round, which required insulation of the external partitions, but this was only possible from the inside due to the historic nature of the façade, which is protected by law. As part of the article, a thermal-humidity analysis of vertical envelopes was carried out regarding the possibility of moisture accumulating in them after thermal modernization and its impact on their technical condition over time. The above-mentioned analysis was carried out with the support of the WUFI 2D program to assess the possibility and amount of moisture accumulation inside the envelopes and on their internal surface, as well as the Physibel Trisco program regarding temperature distribution in the cold season.
The paper aims to present a number of additional standard provisions and changes included in EN 1992-1-1:2023, published in November 2023. Among other features, the new version of Eurocode 2 includes informative annexes on the assessment of existing structures and safety formats for non-linear analysis, which previously were not standardised. In addition, the paper summarises the basic changes of the new standard for the analysis of prestressed concrete structures. The paper also presents an example of the assessment of an existing post-tensioned concrete member in compliance with the recommendations of the EN 1992-1-1:2023 standard. The analyses were performed in two levels of accuracy, i.e. I – analytical method, II – nonlinear FEM analysis. Comparison of the obtained results indicates the potential of nonlinear analysis for optimal assessment of existing structures in accordance with Eurocode 2, especially for non-standard structures, such as prestressed structures.
Distributed Fiber Optic Sensing (DFOS) is a measurement technology that has experienced dynamic development in recent years and is increasingly used in various industries, including construction. By embedding sensors during the manufacturing stage of prestressed concrete elements, significant insights can be gained into their behavior during concrete pouring, prestressing, curing, and under rheological influences. DFOS sensors allow for the analysis of structural behavior under load and changes occurring over time with a level of accuracy previously unattainable with conventional methods. The paper presents research results on the implementation of this technology in pre-tensioned and post-tensioned elements. The main objective of the research was to verify the feasibility of using DFOS sensors to identify damages (e.g., cracks and simulated voids in cable ducts) and monitor the state of deformations and displacements in prestressed concrete elements.
Precast prestressed hollow core floors are able to distribute concentrated loads due to the presence of cast on site joints and torsional stiffness of individual units. By considering this phenomenon in design, the directly loaded element is able to withstand loads much higher than in case of a single element analysis. The current design method provided by European Standard EN 1168 as well as different analytical methods can provide results that do not fully represent the actual performance of the floor. Due to that fact that a sparse amount of experimental data on full scale floor exists, out of which just a handful is documented well, the results of code provisions and analytical models are difficult to evaluate. Based on previous numerical analyses, validated by existing experimental data, numerical models of three hollow core floors were prepared which were used to design new experiments on full scale hollow core floors. Analysis focuses on the Ultimate Limit State of the HC floors, obtained failure loads are compared to single element results and with the results of the EN 1168 standard calculations.
The construction sector contributes to approximately 50% of global carbon dioxide emissions and natural resource consumption, along with generating a significant amount of landfill waste. Thus, there is an urgent need to actively involve our professional community in fostering real environmental change. Embracing circularity in construction presents significant opportunities for decarbonization, particularly in the context of prestressed precast concrete structures. This paper explores the potential for reusing prestressed hollow core slabs already built-in, as well as the principles of designing for future dismantling and reassembly. A second life for hollow core slabs is possible, as has already been confirmed by practical realisations in the Netherlands, Sweden and Finland.
Zagęszczalność materiałów ziarnistych zwiększających trwałość eksploatowanej nawierzchni i podtorza kolejowego
- 1. Politechnika Poznańska, Wydział Inżynierii Lądowej i Transportu, Zakład Budowy Mostów i Dróg Kolejowych
Abstrakt
Postępująca degradacja nawierzchni kolejowej powoduje zwiększenie oddziaływania taboru przekazywanego na torowisko i podtorze, co wymaga zapewnienia odpowiedniego podparcia toru poprzez dobór materiału, uziarnienia czy zagęszczenia warstw ziarnistych. W pracy przedstawiono badania i analizę zwiększonych obciążeń przekazywanych na podsypkę. Poprzez zastosowanie warstw ochronnych podtorza skonstruowanych z odpowiednich materiałów uzyskuje się prawidłowe warunki współpracy nawierzchni i podtorza, zapewniając sprężystą pracę nawierzchni oraz minimalizując jej trwałe odkształcenia. Opisano stosowane obecnie metody i rozwiązania wzmacniania oraz stabilizacji materiałów ziarnistych. Szczególnej analizie poddano zapewnienie odpowiedniego podparcia rusztu torowego poprzez stosowanie właściwego materiału ziarnistego i jego zagęszczenia (w tym niesortu kamiennego uzyskanego z recyklingu podsypki).