30-09-2024 - Original article
Grzegorz Bajorek, Zbigniew Giergiczny

The article presents the concept of concrete durability based on the system of concrete resistance classes to ERC exposure included in the proposed standardization documents (EN 206-1 together with EN 206-100 and Eurocode 2). According to the ERC concept, the performance properties of concrete are tested using recognized test methods, and the results are assessed on the basis of criteria independent of the composition of the tested concrete. The ERC durability concept is open to new technical and standardization solutions in the field of concrete composition (new additives) and cement and should replace the generally applicable prescriptive solutions. This solution is important from the point of view of reducing the emissions of the cement industry (production of multi-component cements and the use of new non-clinker main ingredients) and reducing the carbon footprint of concrete (CO2 reduction classes of concrete according to prEN 206-1)

30-09-2024 - Original article
Piotr Brodniewicz

The paper presents the analysis of basic design tools in the form of standards and literature, that enable the design of timber structures taking durability into account. On this basis, the most important threats were identified and a set of basic design principles was introduced. Then, the identification of risk factors and methods of preventing them were presented, that was based on examples from the designed timber structure of the research and development center

30-09-2024 - Original article
Jacek Dudkiewicz

Owing to the severe impact of the corrosive environment associated closely with the technological process, steel structures, including the columns described in the study, which constitute the main framework of the industrial hall, are prone to corrosion due to inadequate protection. This corrosion has resulted in emergency conditions. The paper presents proposals for strengthening these columns, preceded by expert assessments of their technical condition, geodetic measurements, load-bearing capacity analysis, and an evaluation of the technical feasibility of conducting repairs during continuous industrial operations. The results of these analyses are detailed in this paper

30-09-2024 - Original article
Michał A. Glinicki, Daria Jóźwiak-Niedźwiedzka, Andrzej M. Brandt, Kinga Dziedzic

Diagnostic assessment of industrial floor using the methodology of quantitative evaluation of concrete microstructure is presented. Symptoms of damage included surface dusting and delamination of the top layer. A petrographic analysis of the concrete composition in core specimens was carried out. Excessive air content, accumulation of air voids and the occurrence of oriented cracks, local variability of the phase composition of cement hydration products, including the occurrence of carbonated areas were observed and associated with the premature surface damage

30-09-2024 - Original article
Wioletta Grzmil, Magdalena Tutaj-Dudała

The composition of the binder in cement composites influences the partial or complete restoration of the material's properties during the self-healing process. The subject of the research was the influence of the binder composition on the ability to fill cracks in cement composites. The aim of the research was to assess the effectiveness of reducing scratches during autogenous self-healing of cement mortars with a binder containing metahalloysite and calcium sulphate-aluminate cement. The results of the conducted tests showed that the partial replacement of cement with a calcium-sulfate-aluminate binder and metahalloysite influenced the growth of cracks in the designed cement mortars

30-09-2024 - Original article
Elżbieta Horszczaruk

The paper presents the results of research on the influence of three different types of heavy aggregate (basalt, barite and magnetite) and natural gravel on the abrasion resistance of concrete. Concrete mixtures are designed to obtain maximum resistance to concrete abrasion. Concrete abrasion test was performed using a Böhme disc. The influence of compressive strength and physical and mechanical properties of the used aggregates on the abrasion resistance of the tested concretes was analyzed

30-09-2024 - Original article
Mateusz M. Iwański, Małgorzata Durlej

The article presents the results of structural research on the analysis of pore density in a asphalt mixture using X-ray CT. The impact of the amount of bitumen on the compactness of total voids and the water resistance of the asphalt mixture was assessed using traditional standard methods. Then, its external structure was examined, which allowed to explain the mechanism of changes occurring in the structure as a result of the impact of water on it. The information obtained during the test regarding the distribution of pores, their size and number allows for the correct selection of the amount of binder in the asphalt mixture and its diagnostics in terms of durability in the structural layer of the road pavement in terms of water resistance

30-09-2024 - Original article
Marta Kadela, Alfred Kukiełka

Although foamed concrete was practically created about 100 years ago, there are no current standards for foamed concrete and test methods for determining its properties. Hence, while the assessment of mechanical properties can be found in the literature, the assessment of the durability of foamed concrete is rare and is most often carried out due to a specific impact or for a specific composition of foamed concrete. Therefore, this work presents the results of tests on foamed concrete with densities ranging from 600 to 750 kg/m3 subjected to freeze-thaw cycles. Based on the results of the tests, it was found that the tested foamed concrete met the requirements of the PN-B-06265 standard for the freeze-thaw resistance degree F25

30-09-2024 - Original article
Artur Koper, Karol Prałat, Justyna Ciemnicka, Małgorzata Brych-Dobrowolska

The article presents the results of tests of concretes based on natural aggregate and recycled ceramic aggregate (ceramic sanitary aggregate). Two types of recycled aggregates were used: FFC – ceramic aggregate without fireclay and VC – ceramic aggregate with fireclay). The recipe composition for the reference mixture was designed experimentally, assuming a w/c = 0,5 and plastic consistency. In the next stage of the research, 30% and 60% of the natural aggregate was replaced with recycled ceramic aggregate and the obtained results were analyzed. Water absorption, compressive strength and compressive strength after calcining were tested (max. temperature 750°C)

30-09-2024 - Original article
Tomasz Mioduszewski, Aleksandra Maliszewska, Aleksandra Lewandowska, Aleksandra Wawrzyńska

Most offshore hydrotechnical structures, once completed and put into service, work both above and below the water surface. Modernization, repair or reinforcement of concrete or reinforced concrete structures in constant contact with salt water poses many problems. The most difficult task is to ensure and maintain efficiency, as well as continuity and readiness to work during the renovation of the structure. The paper presents examples of concrete corrosion that can occur in marine breakwaters; the types of impacts are defined, as well as the associated types of corrosion. The main part of the publication consists of actual examples of damage to concrete walls of water side walls of breakwaters, as well as designed repair methods and their implementation. In addition, the Reader can see photographic documentation of the structure showing both the scale of corrosion damage, repair work and the final result

30-09-2024 - Original article
Paweł Niewiadomski, Elżbieta Janowska-Renkas, Michał Cisiński

This paper presents the results of research aimed for evaluating the impact of applicability of spent fluid catalytic cracking catalyst as a substitute of 20, 40, 60 and 80% of cement, by mass, in cement mortars on their selected mechanical and physical performances. It was demonstrated that substitution of 20% of cement mass with spent catalyst enhanced mortar’s compressive strength for 16.7%. Further addition of spent catalyst tended to decrease strength, whilst, simultaneously, rose the values of capillary absorption and water absorptivity because of deterioration of cement matrix structure, documented by SEM photos. Based on the research and literature data, it was proved that spent cracking catalyst might be a promising additive to cement in the amount not exceeding 40% of its mass considering its pozzolanicity

30-09-2024 - Original article
Zbigniew Perkowski, Jadwiga Świrska-Perkowska, Mariusz Graba, Andrzej Marynowicz, Mariusz Czabak, Andrzej Kucharczyk, Kamil Pawlik, Daniel Frączek

The work concerns the diagnostics of the thermal and humidity condition of the external wall of a real building, insulated with an additional layer of mineral wool in the ETICS system. Eight sensors were placed in four different sections of the envelope, located at the boundaries of its layers, to monitor changes in air temperature and relative humidity. The measurements were carried out from January 2024. The data obtained from the experimental tests were compared with the simulation calculations using the coupled two-component Künzel model. Discrepancies were found between experimental and computational data

30-09-2024 - Original article
Dominika Stańczak, Maja Kępniak, Magdalena Horbaczewska, Beata Jaworska

In light of the growing issue of climate change, it is necessary to take actions aimed at reducing the emissions of carbon dioxide (CO2) into the atmosphere. CO2 sequestration, especially in the process of concrete production, can be a crucial step in combating this phenomenon. The study attempted to utilize recycled aggregate for CO2 sequestration and assess its effect on the carbonation depth of the mortar. The loss on ignition analysis of the aggregate showed a 2.9% CO2 absorption. Mortar with carbonated aggregate exhibited the highest degree and depth of carbonation among the tested specimens, albeit eight times lower than the depth typically containing reinforcement bars

30-09-2024 - Original article
Agnieszka Wdowiak-Postulak, Grzegorz Swit, Aleksandra Krampikowska, Justyna Zapała-Sławeta, Wioletta Grzmil, Peter Koteš, Jozef Gocál, Frantisek Bahleda, Jozef Prokop

The paper describes a program of experimental and numerical tests aimed at determining the mechanical properties of beams made of laminated timber (BSH) and laminated veneer lumber (LVL) reinforced with pre-stressed bars made of basalt, glass, natural and steel fibers, basalt mats with roving and composite, polyethylene and natural yarn. The paper presents various types of reinforcements, the purpose of which was to obtain higher load-bearing capacity and stiffness in bending with shear than for unreinforced beams. The effectiveness of different reinforcement schemes was compared for seventeen beams subjected to experimental tests on a test stand, the modes of destruction were described, as well as mechanical properties, deformations and deflections for reinforced and unreinforced beams under multiply variable and long-term loading. Based on the experimental studies, a significant increase in the load-bearing capacity and stiffness of the reinforced beams subjected to simultaneous bending and shear was confirmed, and it was indicated that the reinforcements by pre-stressed bars (steel, with polymer reinforcement or natural fibers) and composite mats eliminated local defects and discontinuities in the wood, without affecting the quality and strength of the FRP-wood connection. The numerical results of the analysis of the beam models using the finite element method showed compliance with the experimental studies in terms of deflections, linear and angular strains for the reinforced and unreinforced beams

30-09-2024 - Original article
Alicja Wieczorek, Monika Trzuskowska, Piotr Wróbel, Marcin Koniorczyk

The objective of the study was to determine the suitability of fly ash derived from the combustion of hard coal in a heat and power plant located in Lodz to produce geopolymer. The study investigated the effect of the molar modulus of the activator (SiO2/Na2O) on the compressive strength over time in mortars modified with the addition of granulated blast furnace slag (0, 10 and 50%). An important aspect of the analyses is the possibility of managing locally occurring products from industrial processes

30-09-2024 - Original article
Kamil Załęgowski, Maja Kępniak

Partial replacement of quartz flour microfiller in polymer composites with biocarbon is one of the potential ways to utilize this waste. The article discusses the possibility of using biocarbon as a component of vinyl ester mortars, in the context of their chemical resistance. The tests were carried out for mortars with different quantitative compositions, and therefore with different biocarbon contents. They were subjected to 12-month exposure to a chemically aggressive environment. Solutions of 0.5% sulfuric acid(VI) and 5% sodium hydroxide were used. Measures of resistance were changes in weight, compressive strength, longitudinal ultrasonic wave velocities and quantitative changes in microstructure compared to chemically unstressed samples. The results show that vinyl ester mortars with biocarbon are more resistant to chemical aggression with sulfuric(VI) acid solution. A significant decrease in compressive strength, ultrasonic wave velocity and an increase in the values of stereological parameters were observed after exposure of the composites in sodium base solution. This is in contrast to the chemical aggression in the acid solution, after which the changes in the properties and microstructural parameters of the mortars were not so clear

30-09-2024 - Original article
Mateusz Chludziński

The paper describes an attempt to include the effect of vibroflotation on the quay wall in the numerical analysis. An axisymmetric FEM model was made, in which the increment of pressure on the steel wall, caused by initiated horizontal displacement, was checked. The stress read off in this way has been implemented in the plane strain model of the quay wall. The results of the internal forces and deformations are presented. The displacements were collated with the geodetic survey

30-09-2024 - Popular science article
Remigiusz Duszyński, Katarzyna Zamara

Geosynthetics have been used for decades in infrastructure construction, especially in traffic construction and geotechnics. Despite this, there is still a relatively low uptake of methods for designing solutions using these materials. While the applications of geogrids (or more broadly: geosynthetics) in reinforced soil structures (retaining walls, steep slopes) and the associated design methods are well described in the literature and standards, there is much more modest knowledge available on applications related to the reinforcement of the subsoil directly under road and railway pavement structures, the construction of working platforms on soils with very low bearing capacity, or increasing the fatigue life of the pavement itself. This situation is due, among other things, to the fact that different geosynthetics, including different geogrids, affect the bearing capacity of the subsoil and the durability of the structure in different and often very different ways. Hence – unlike, for example, in the case of retaining walls – it is difficult to develop a one-size-fits-all design method covering this range of applications. It is necessary to rely on the experience of manufacturers of particular varieties of geogrids or geo-grids and to use design methods developed by them based on this experience. This article presents the technology of geocellular mattresses used primarily in the base of embankments on weak and deformable grounds, as well as for the construction of temporary working platforms. The performance of structures in complex and complicated geotechnical conditions is analysed on the example of completed projects. The results of back analysis of structures subjected to real-scale tests are presented, which can be used for preliminary analysis of solutions in numerical modelling programmes

30-09-2024 - Original article
Krystyna Jaśkiewicz

Despite the passage of time, ISO standards for description and classification have not been fully adapted to common and correct use in practice. This article presents the methods of identification, description and classification of soils contained in PN-EN ISO 14688-1:2018-05 and PN-EN ISO 14688-2:2018-05 in practical terms. The level of detail of description depends on the properties of the soil in question, the size and quality of the soil sample as well as the purpose of their collection within the framework of the design or reconnaissance task performed. In this regard the practice of PN-EN ISO 14688-1:2018 soil determination and description varies. The article gives examples of soil determination based on the above-mentioned ISO standards in field and laboratory tests. Problems were observed due to, among other things, the translation of the standard as well as unspecified issues of description. Most soils usually include more than one fraction. A distinction is made between the main fraction and secondary fraction, as well as a tertiary fraction in justified cases. In the determination of the main fraction in practice there is no trouble, so in the case of multifractional fine-grained soils, the lack of a direct and unambiguous way to record the secondary fraction causes difficulties for the assessor resulting in discrepancies in the soil description

30-09-2024 - Original article
Grzegorz Sołtys, Artur Zachodni

This paper presents a numerical analysis of the displacement of the substructure for the construction of the S1 route bypassing Węgierska Górka. The numerical analysis includes displacement calculations taking into account the ground anchor stiffness obtained in acceptance tests. The results of the analysis were compared with monitoring measurements. A sensitivity analysis was carried out in relation to the soil parameters used and the achieved ground anchor stiffnesses

30-09-2024 - Original article
Krzysztof Żarkiewicz, Zygmunt Meyer

One of the field soil tests commonly used for pile design is CPTu static sounding. The load-bearing capacity of pile foundations is commonly verified in field experiments through static load tests. The result of this test is the load-settlement relationship of the pile which can be approximated by a curve named M-K. The main aim of the work is to check the possibility of determining the parameters of the M-K curve based on the results of field tests with the CPTu sounding. Experimental research leads to relationships between the parameters of the M-K curve and geotechnical parameters, including CPTu static sounding. The paper presents the possibilities of using the CPTu sounding to estimate the pile settlement curve. Knowledge of this relationship at the foundation design stage allows you to confirm whether the pile meets the load-bearing conditions and to determine the safety margin, which gives designers greater opportunities to correctly design the foundation

 
30-09-2024-Original article - Pages: 492 - 497

Analysis of the possibility of description the pile load-settlement curve based on the CPTu results

  • 1. Zachodniopomorski Uniwersytet Technologiczny w Szczecinie, Wydział Budownictwa i Architektury, Katedra Geotechniki
  • 2. Zachodniopomorski Uniwersytet Technologiczny w Szczecinie, Wydział Budownictwa i Inżynierii Środowiska. Al. Piastów 17, 70-310 Szczecin, Wydział Budownictwa i Inżynierii Środowiska
Published:30-09-2024

Language versions:
60
DOI:10.5604/01.3001.0054.7493
GICID:01.3001.0054.7493


 

Abstract

One of the field soil tests commonly used for pile design is CPTu static sounding. The load-bearing capacity of pile foundations is commonly verified in field experiments through static load tests. The result of this test is the load-settlement relationship of the pile which can be approximated by a curve named M-K. The main aim of the work is to check the possibility of determining the parameters of the M-K curve based on the results of field tests with the CPTu sounding. Experimental research leads to relationships between the parameters of the M-K curve and geotechnical parameters, including CPTu static sounding. The paper presents the possibilities of using the CPTu sounding to estimate the pile settlement curve. Knowledge of this relationship at the foundation design stage allows you to confirm whether the pile meets the load-bearing conditions and to determine the safety margin, which gives designers greater opportunities to correctly design the foundation