30-06-2025 - Original article
Zdzisław Pisarek

In construction works, composite structures are currently very popular types of structures, where a massive reinforced concrete slab is used to transfer compressive forces, and a steel section takes over the tensile forces. Composite slabs on corrugated sheets are also often used, which allow the use of time-consuming and expensive full formwork to be avoided. The cooperation of a reinforced concrete slab with a steel frame requires the development of new types of steel frame connections with a structure that allows for obtaining sufficient moment resistance during assembly and full moment resistance when working with a reinforced concrete slab. The article presents a proposal for a steel joint using an assembly table and a gusset plate intended for composite structures and methods for calculating its moment resistance

30-06-2025 - Original article
Andrzej Wojnar, Wiktoria Kasprzak

An internal gas explosion in an enclosed hall space generates a rapid increase in temperature and pressure, resulting in damage to the building structure and posing a potential threat to human safety. The impact of the explosion on the industrial hall structure causes deformation or destruction of key and secondary elements of the load-bearing structure, wall cladding systems and roof sheathing. This paper presents one method for verifying the stability of a steel structure subjected to a load such as an internal gas explosion. Theoretical aspects, a calculation algorithm and a case study are discussed. The loading due to an internal gas explosion was modelled using the equivalent static method

30-06-2025 - Original article
Marcin Górski

The article presents a proposal for the calculation of column bases with stiffeners, taking into account the assumptions made in the Eurocodes. The procedure is based on the compatibility of the displacements of the characteristic points of the column base and the foundation. In the compression zone, the plastic distribution of stresses in concrete and the accompanying limit strains were assumed in accordance with Eurocode 2, while in the tension zone the deformations of the column base were taken into account based on the stiffness coefficients given in Eurocode 3. A calculation example is presented and the results are compared with the IdeStatica program based on the component method and FEM analysis

30-06-2025 - Original article
Paweł Kawecki

Methods for assessing the structural properties of bolts in beam endplate connections are presented. Attention is paid to the change in bolt behaviour depending on the length of the thread in the clamping part, the influence of the testing method and modelling on the conclusions about the strength properties of the fasteners

30-06-2025 - Original article
Damian Kukla

The article presents challenges, preparations and selected results from the first experimental tests in Poland of bolted end-plate joints of steel structures subjected to impact loading. The tests were carried out on specimen in a cross beam-column-beam configuration using bolted end-plate joints. The impact energy was generated by a free falling steel-concrete package. Special measuring equipment dedicated to dynamic tests was used. The tests focused mainly on measuring deformations and displacements. The obtained test results allowed determining the strain rate and the dynamic influence factor (DIF) for selected specimen elements. The end-plate joints showed significant ductility and load-bearing capacity during the test. The weakest component of the joint turned out to be the bolts

30-06-2025 - Original article
Krzysztof Ostrowski

The article presents the results of a numerical analysis of a selected configuration of a bolted end-plate beam-to-column connection, with particular emphasis on the influence of the failure model on the values and distribution of axial forces in the bolts. A definition of the joint rotation capacity is given, based on the criterion of the maximum force a bolt can sustain in laboratory testing. For the average maximum force in bolts (M20, grade 10.9), a reduction factor BT of 0.90 was adopted to eliminate the occurrence of plastic strain. The force value BT = 240 kN was taken as a reference for determining the ultimate rotation angle u. The analysis involved a column with a HEB500 cross-section, connected to beams with cross-sections HEA280, HEA300, HEA320, HEA340, HEA360, and HEA400. Numerical simulations were performed using end plates with thicknesses of 12, 15, and 20 mm. The model was built based on the results of a calibration procedure involving multi-stage hierarchical validation. The force distribution in bolts was analyzed for the three different plate thicknesses (20, 15, and 12 mm), allowing for a detailed assessment of the influence of joint stiffness on the load transfer efficiency by individual bolt rows. In configurations characterized by dominant end-plate yielding and significant elastic-plastic rotation, a favorable redistribution of forces among bolts is observed. Connections that exhibit high load-bearing capacity do not show significant increases in rotation capacity. These are cases where the failure mode, governed by bolt yielding, becomes the decisive factor. The introduction of a joint rotation angle definition, based on laboratory test results of the ultimate bolt force (90% of the average failure load for M20 bolts, grade 10.9, ISO 4014), enabled the establishment of an objective criterion for evaluating the rotation capacity of the connection

30-06-2025 - Original article
Edyta Bernatowska, Zbigniew Kiełbasa

The article presents proposed reinforcement solutions for the steel structure of the main nave of a gymnasium that was under construction. During the erection of the structure, the contractor raised concerns regarding the adequacy of certain structural solutions specified in the design documentation. A site inspection and a preliminary review of the project documents confirmed the presence of design deficiencies, such as a lack of continuity in the chords of the truss girders, insufficient capacity of some connections, and incorrectly designed bracing systems. These flaws led to violations of both ultimate and serviceability limit states of structural elements. As a result, it became necessary to develop reinforcement measures and to incorporate the contribution of the roof cladding into the overall structural performance. The implementation of the proposed solutions ensured the reliability and structural integrity of the gymnasium hall

30-06-2025 - Original article
Wiesław Kubiszyn

The article presents issues related to the shaping and design of steel liners in industrial chimneys, steel, ceramic and reinforced concrete. The design of steel liners is governed by the principles and requirements specified in Eurocodes PN-EN 1993-3-2 and prEN 1993-3, as well as related standards: PN-EN 1993-1-6; PN-EN 13084-1; PN-EN 13084-6 and PN-EN 13084-7. The principles of design and adopted material solutions for steel liners are described. The principles of designing these liners taking into account the effect of temperature difference and the effect of deformation or displacement of the chimney shaft are also presented. In conclusion, the article recommends the realization of steel double skin chimneys with a stainless steel liner as a solution that meets the standard requirement for the durability of steel chimneys

30-06-2025 - Original article
Rafał Budziński

An algorithm for the calculations of stiffness of bolted shear lap connections according to the second generation of EN-1993-1-8, based on the linear and non-linear definition of the component of bearing at the bolt hole is presented in this paper. Following the guidelines of the standard and the structural and assembly conditions, an approach for the determination of simplified force-displacement response is presented for exemplary connections, together with a comparison with experimental results

30-06-2025 - Original article
Lucjan Ślęczka, Marcin Gryniewicz

This publication outlines the principles for evaluating the load-bearing capacity and fatigue performance of bolted flange connections in accordance with the provisions introduced by the second generation of Eurocodes. The proposed assessment procedures are compared against the methodologies traditionally applied in Polish engineering practice

30-06-2025 - Original article
Lidia Buda-Ożóg, Damian Nykiel, Katarzyna Sieńkowska-Szpetnar, Agnieszka Głuszko

The objective of this study was to analyse the behaviour of reinforced concrete flat slab structures under an emergency scenario involving the loss of an edge support column. The methodology and findings of experimental tests conducted on a single-storey model are described, along with numerical simulations performed using ATENA Static software for one- , two-, and four-storey buildings. The results of the analyses demonstrated a significant influence of upper storeys on the deformation mechanism and load redistribution within the slab following column failure. In multi-storey buildings, a notable reduction in deflections was observed in comparison to the single-storey structure. Furthermore, the analysis of forces in columns located above the damaged element revealed a change in their nature from compressive to tensile, indicating the activation of a catenary action mechanism that assists in load transfer. The study established the crucial role of adequate peripheral reinforcement in the slab and reinforcement in the columns, enabling their tensile behaviour in an emergency situation

30-06-2025 - Original article
Anna Barszcz, Marian Giżejowski, Izabela Wójcik-Grząba

Problems of computation and graphical interpretation aspects of the relationship between the maximum moment Mcr,N of the member bent about the major axis, and the compressive axial force N. Detailed considerations are related to a monosymmetric I-shape section of prismatic simply supported members with the ends of free warping and under the uniformly distributed load qz over the entire length. The obtained results are compared with those based on the analytical solution available in literature and with those from the computer program LTBeamN

30-06-2025 - Original article
Jakub Marcinowski

The method of designing stiffening rings of a steel tank shell is specified in the rules included in Eurocode EN 1993-4-2 in force since 2007 and in its national version of 2009. A reservation regarding the correctness of one of the formulae was raised in 2015 by Prof. Aleksander Kozłowski. The amendment of the disputed formula was adopted by the CEN/TC 250/SC 3/WG 16 working group developing the second generation of Eurocode EN 1993-4-2, which will enter into force in 2027. The paper presents the scientific basis of the rules contained in the standard and the history of Prof. Kozłowski’s effective intervention

30-06-2025 - Original article
Szymon Szewczyk, Robert Studziński

Modern structural design practice relies heavily on the development of advanced computational models that serve as the basis for strength and stability analyses. A computational model, as a simplified and idealized representation of the actual structural system, should closely reflect the real behavior of the structure under the applied loads and adopted design solutions. This paper reviews essential aspects of modeling steel structures, with particular emphasis on the effects of geometric nonlinearity and structural imperfections. Differences between the first and second generation of Eurocode 3 in the field of global structural analysis are discussed, highlighting the increasing importance of aligning the computational model with the actual structural behavior. In the present study, only geometric nonlinearity is considered, assuming a linear-elastic material model. The aim of this paper is to identify key factors affecting the accuracy and reliability of analysis results in steel structures and to outline the limitations imposed by the adopted modeling assumptions. The presented considerations provide practical support for structural designers in making informed engineering decisions regarding the appropriate level of complexity in structural analysis

30-06-2025 - Original article
Robert Studziński, Paweł Ordziniak

Steel frame structures are a widely used solution in industrial and commercial construction, where properly designed bar connections play a key role in ensuring effective force transmission and structural continuity. This paper presents a classification of connections commonly used in steel structures and discusses their impact on the load-bearing capacity, stiffness, and deformability of the entire structural system, in accordance with the requirements of the PN-EN 1993-1-8 (EC3) standard. Special attention is given to the modelling of beam-to-column connections in portal frames, with a focus on the eaves joint area, where longitudinal haunches are frequently applied. The aim of this study is to analyse the influence of different modelling approaches for haunches on the distribution of internal forces and the resulting design implications. The importance of accurate joint modelling in the context of structural analysis and design is highlighted, with particular emphasis on safety, reliability, and economic efficiency in the execution of steel structures

30-06-2025 - Original article
Katarzyna Rzeszut, Maciej Adam Dybizbański

This paper presents the results of laboratory tests obtained using the ARAMIS 6M digital image correlation method. The displacement measurement and deformation assessment were carried out for CFS beams with a cross-section of 200×70×2 and a span of 2700 mm, made of S350GD steel, reinforced and unreinforced (reference), loaded in a four-point bending scheme. The beams were reinforced with SikaWrap 230 C fabric glued to the edge stiffeners using SikaDur 330 adhesive. The tests were carried out for two cases, i.e., with the possibility of cross-section deplanation at the supports and for the lack of deplanation at the supports. Based on the obtained results, it was found that in the case of vertical and horizontal displacements, the use of the proposed reinforcement has a particularly beneficial effect for the case when there is no possibility of cross-section deplanation at the supports.

30-06-2025 - Original article
Mariusz Maślak, Paulina Zajdel, Piotr Kuraś

The load-bearing capacity specified for flexural buckling and related to fire conditions was precisely determined. It was identified for corresponding columns with identical geometry and support method, made of stainless steels of various types, with differentiated crystal structures. For comparative purposes, the obtained results were referred to the analogous load-bearing capacity of the same columns, designed this time from non-alloy structural steels of selected types, associated with the previously considered stainless steels due to their similar strength. It was shown that the internal structure of a stainless steel determines its fire resistance. In general, however, this resistance is significantly higher in relation to that which characterizes the typical non-alloy structural steels.

30-06-2025 - Original article
Martin Mensinger, Piotr Woźniczka, Maria-Mirabela Firan

The selected results of experimental research on fire resistance of hot-dip galvanized steel structural members are presented in this paper. Experimental studies carried out included fire tests of full-scale steel composite beams, various types of steel joints and three types of specimens. The composite beams were made of S355J2, S460M and S690QL steel grades, while the specimens were made of S355J2+N steel, which was classified in category B or D according to PN-EN ISO 14713-2 standard. Weathered and unweathered specimens were taken into account. As a result, proposed values of surface emissivity have been presented. The potential impact of soot has been also taken into account. The use of the recommended emissivity values in the fire resistance analysis can reduce the need for expensive fireproof insulation.

30-06-2025 - Original article
Jan Zamorowski, Grzegorz Gremza

Steel structures, as a significant part of modern civil engineering, offer numerous opportunities for the integration of artificial intelligence (AI) technologies – ranging from technical optimization and process management to structural health monitoring. This article aims to present and analyze current and potential applications of AI in the domain of steel structures. It provides a classification of selected AI methods, explores their use in the design, analysis, assembly, and monitoring of steel structures, and discusses key challenges along with potential directions for future development.

30-06-2025 - Original article
Przemysław Krystosik

This paper presents an algorithm for evaluating the resistance and stiffness of a column base, based on the component method. The first part of the paper characterizes the adopted solution for the column-to-foundation connection, whose main element is a double-cantilever I-beam. The bottom flange of this beam is anchored into the concrete foundation using anchor bolts, while the shaft of the column is attached to the top surface of the upper flange of the beam. Based on the guidelines of the EN 1993-1-8 standard, literature studies, and the author's own analyses, fundamental equations were established for calculating the mechanical properties – resistance and stiffness of individual components of the column base. Subsequently, mechanical models of the analyzed solution were formulated, serving as the basis for determining the relationships for the base’s overall resistance MRd and stiffness S. The final part of the paper includes a numerical example demonstrating the application of the proposed procedure in the calculations of the reinforced column base.

30-06-2025 - Original article
Kamil Słowiński, Marek Piekarczyk

The article discusses the effect of various methods for modelling the wind girder on the stability assessment of the shell of open-top tanks, conducted using the MNA-LBA dimensioning procedure in accordance with the PN-EN 1993-1-6 standard. In the context of applying this procedure, the question arises about the influence of the wind girder modelling method on two key parameters essential for evaluating the relative slenderness of the shell, namely the critical load-bearing indicator rRpcr and the plastic load-bearing indicator rRpl. For a formal assessment of overall relative slenderness of the shell, both of these indicators must be determined as accurately as possible. A series of numerical analyses were conducted using models with varying levels of accuracy in the representation of the wind girder. The results of these analyses helped address problematic issues related to the interpretation of the results needed for a reliable assessment of the stability of the shell of open-top tanks.

30-06-2025 - Original article
Bartosz Zdziarski, Łukasz Polus, Marcin Chybiński

In this paper the material costs of beams made of different materials were compared. Steel and steel-concrete composite beams were compared with a steel-timber composite beam. In the case of a ceiling composed of beams and slabs, steel-timber composite beam had the most favourable bending resistance to mass ratio.

30-06-2025 - Original article
Krzysztof Wierzbicki

The article presents the results and conclusions of experimental tests on six-metre steel beams with an IPE180 cross-section in a simply supported beam scheme reinforced with batten plates. As part of the tests, a test stand was designed and constructed, which allowed a concentrated force to be applied in the middle of the span of the tested beams. The tests assumed that three beams would be reinforced under a preliminary load causing a stress exceeding 50% of the bending capacity of the element with buckling. The next three beams would be reinforced without initial loading. Batten plates were used as reinforcing elements, which were welded to the tested beams in the support zones. After reinforcement, an increase in the load-bearing capacity of the beams by approximately 25% was observed, and no significant effect of the preload on the final load-bearing capacity of the elements was observed.

30-06-2025 - Original article
Tomasz Arciszewski, Fodil Fadli

„Resilience Engineering” (RE) is a new emerging engineering science. Its importance is rapidly growing because of the rising size and complexity of infrastructure objects. The subject of this science is resilience of infrastructure objects understood as an emerging feature related to their ability to survive and work in an evolving environment and outside of the envelope of their design assumptions. The paper’s goal is to interest Polish scholars and designers in resilience and to propose 10 research challenges, to be addressed to create a theoretical foundation necessary to use RE in designing and analysis of existing infrastructure objects. In the paper’s first chapter the necessity to develop RE was justified and an example was provided demonstrating how the lack of resilience of a bridge structure for collisions with large ocean container ships may cause huge economic and social losses. In the next chapter, was provided a working definition of infrastructure objects resilience and its understanding in the context of complex systems. Also, the notions “Safety” and “Resilience” were compared with appropriate examples. Next, three classes of resilience (Static, Dynamic, and Evolutionary) with examples, five levels of resilience, seven eventual resilience criteria and a resilience estimation formula were proposed. In addition to the notion of resilience, the notions of fragility of infrastructure objects and antifragility of infrastructure objects were introduced and explained using examples. In the third chapter the complexity of factors affecting resilience was discussed using a comparison of two tall building: World Trade Center (WTC) in New York City, USA and the Prudential Building in Warsaw, Poland. In the fourth chapter, ten research challenging were proposed to initiate a discussion on the future Polish resilience research. Finally, Final Remarks were presented.

30-06-2025 - Original article
Tadeusz Zwoliński

The aim of the study was to develop guidelines for the rational design of braced steel structures using a 2D tower model as an example. The analyzed structure was 20 meters high and 4 meters wide, consisting of columns, horizontal beams, and X-type bracings. Seven bracing configurations were considered, with bracings placed across two to seven levels. All structural elements were made of S235 steel. Bracings were modeled as solid round bars, beams as SHS profiles, and columns as catalog sections: HEA, HEB, SHS, and CHS. A total of 367 column cross-sections were analyzed across seven bracing layouts. Design guidelines for bracings were presented and discussed, with a focus on eliminating lateral-torsional buckling, based on two key criteria: stiffness and load-bearing capacity. Structural calculations were carried out using Robot Structural Analysis software, applying a linear buckling analysis (LBA) with reduced stiffness. In total, 2,202 towers with optimally selected bracings and beams were designed. The results were compiled to show structural efficiency (tower capacity to weight ratio) depending on the slenderness of the columns. It was found that the most effective designs used low-slenderness columns, and the mass of bracings and beams should generally not exceed 25% of the total tower weight.

 
30-06-2025-Original article - Pages: 313 - 320

Obliczenia wzmocnionych podstaw słupów według metody składnikowej

  • 1. Politechnika Koszalińska, Wydział Inżynierii Lądowej, Środowiska i Geodezji
Published:30-06-2025

Language versions:
16
DOI:10.5604/01.3001.0055.1611
GICID:01.3001.0055.1611


 

Abstrakt

W artykule przedstawiono algorytm oceny nośności i sztywności podstawy słupa, który oparto na metodzie składnikowej. W pierwszej części pracy scharakteryzowano przyjęte rozwiązanie połączenia słupa z fundamentem, którego zasadniczą częścią jest dwuwspornikowa belka o przekroju dwuteowym. Dolny pas tej belki utwierdzono w podłożu betonowym za pomocą śrub kotwiących, podczas gdy do wierzchniej powierzchni pasa górnego belki zamocowano trzon słupa. Na podstawie wytycznych normy PN-EN 1993-1-8, studiów literaturowych oraz własnych analiz określono podstawowe związki do obliczeń cech mechanicznych – nośności i sztywności poszczególnych składników podstawy. Następnie sformułowano modele mechaniczne analizowanego rozwiązania, które stanowią podstawę do określenia nośności MRd oraz sztywności S całej podstawy. W końcowej części pracy zamieszczono przykład liczbowy, w którym przedstawiono zastosowanie prezentowanej procedury w obliczeniach wzmocnionej podstawy słupa.